InteliCENTRIC IME

ECCENTRICITY MEASUREMENT

The Proton IME Non-Contact Eccentricity and Diameter gauges measure high-frequency data cables such as Local Area Network {LAN} cables, electronic and automotive wires, where eccentricity measurement is critical for cable performance and quality.

IME gauges measure eccentricity, diameter and detect flaws at high line speeds, thanks to the lightning-fast scanning speed of 100 kHz per axis.

Automatic position adjustment ensures the cable is centered within the measuring zone. A built-in or remote CDi4 display provides a clear visual display of diameter and 8-point eccentricity, and optional statistical features.

The IME2012-i4 and IME4012-i4 can be integrated into the production line or can operate standalone.  All communication protocols needed to integrate into the production line are provided as standard and include PROFIBUS, PROFINET, and Ethernet Industrial Protocol for PLC connection, Modbus, OPC-UA, RS232, RS485 and WiFi.

  • Lightning-fast measurement rate: 100,000 scans/s/axis
  • Automatic gauge head position adjustment
  • 8-point eccentricity
  • Non-contact measurement
  • Eccentricity update rate: 1 ms
  • Eccentricity resolution: 0.1 ?m (0.000004 in)
  • PLC integration, or use stand-alone
  • FFT – Fast Fourier transform analysis of periodic diameter variations
Manual & Docs Request A Quote

Performance

IME2012-i4 IME4012-i4
Number of axes 2 4
Gate size 16 mm
0.59 in
16 mm
0.59 in
Min object diameter 0.1 mm
0.004 in
0.1 mm
0.004 in
Max object diameter 12 mm
0.47 in
12 mm
0.47 in
Resolution 0.01 µm 0.01 µm
Diameter accuracy +-1 µm
(0.00004 in)
+-1 µm
(0.00004 in)
Eccentricity accuracy +-1 µm
(0.00004 in)
+-1 µm
(0.00004 in)
Optical scan rate 10000/s/axis
Eccentricity update rate 1 ms
Units Diameter measurement selectable mm, inch

Connectivity

Analog input 0 to 10 Vdc
Required for Optional PI feedback diameter control and SMFD location

Pulse Input 250 kHz max frequency, 30 V or 50 V max pulses on two distinct inputs.
Required for Helix Mode, Tolerance Location and Optional SMFD and PI feedback diameter control.

Maximum Voltage 50 Vdc / 30 VAC / 0.5 A
Selectable function: Gauge OK, Eccentricity Tolerance exceeded, Upper Tolerance exceeded, Lower Tolerances exceeded, Single Measurement Flaw Detection ( SMFD ) , Over any ( Limit ), Under any ( Limit ), Lump & Neck, Lump, Neck, Over average, Under average, Window dirty.

RS232 Modbus Communications
USB using RS232 – USB Converter Cable
ZM4000 Printer Communications

Ethernet TCP/IP Modbus is the Default Communication. Connect to a PLC using PROFIBUS, PROFINET, or EtherNet I/P.

Ethernet selectable between OPC-UA and Modbus

Connect to a PC or mobile device and use the Proton Products Gauge
App. Ideal for gauge configuration and diagnostics.

Gauge Head Add on Hardware

3 analog (+10 V) outputs can be set to X, Y, Z-axis output for 2 and 3 axis gauges. Average diameter, diameter error, ovality, and ovality error.

Feedback Control monitors the actual measured diameter compared to a Preset Value and provides a Control Output Signal that can be used to trim the motor output and maintain the product diameter within the Preset Value.

Gauge Head Add on Software

The 10k scanning option upgrades the standard gauge to enable a high scan rate that can be used for effective flaw and defect detection, each scan takes just 1ms to obtain and output a new diameter reading.

Maximum, Minimum, Mean, Standard Deviation, Cp, Cpk is collected during a selectable time or length period. The results are updated on the CDi4 Universal Display, PGIS Software and can be transmitted digitally.

Statistical Process Control (SPC) enhances the Feedback Control option. Statistical Process Control, “measures” Process Capability and automatically adjusts the control setpoint to maximize material savings while maintaining control within upper and lower limits.

Fast Fourier Transform (FFT) analyzes the diameter data for periodicity. Providing Amplitude versus Frequency data and a graphical representation on the CDi4 Universal Display Unit or PCIS Software.

Single Measurement Flaw Detection (SMFD) analyzes each individual measurement and compares it with the running average. If a Single Measurement is greater than the running average and above a threshold value a Flaw is Detected.

Measuring Principle

Laser DopplerThe Eccentricity Gauge combines electromagnetic and optical scanning principles. The optical scanning system is used to define the wire insulation outer diameter and the electromagnetic system is used to determine the wire core position, eccentricity and 8 point wall thickness.

Optical measurement is done by sending out light from LEDs which shine on the measuring object thus casting a shadow on the CCD receiver. The image information is then evaluated by integrated signal processors.

The optical measurement and magnetic measurement are performed simultaneously at high rates, minimizing inaccuracies caused by wire vibrations, and both measurements are controlled on the same plane to eliminate the errors due to product twists.

Electrical and Operating Requirements

Power Supply Power Consumption Operating Temperature Environmental Protection
85 to 274 VAC 300 Watts 5 °C to 45 °C (41 to 113 °F) IP65

Size & Weight

Height
1166 mm (45.9”)
Depth
360 mm (14.2”)
Width
142 mm (5.6”)
Weight
45 kg (99 lbs)